TECHNICAL SPECIFICATIONS
Aluminium anodised
under-frame
Stainless circuit
Polypropylene tank 75L with lowest level detector
Fluid
Circulation pump
Flow 10 m3/h
Safe valve with return to the tank
Flow meter with magnetic transmission float
Scale 10m3/h precision 1.6%
Compensation of viscosity in function of the temperature
Tube rectifier
Stainless steel material
Pipe to study
Length 2.5m diameter 19mm
10 plug of pressure linked to piezometer tubes
Transparent flow chamber
Transparent Plexiglas front
Cellular jet breeze |
Speed profile measurement in a pipe DN
100
Use of Pitot tube
According to the regulation...
KELLER differential pressure sensor
Scale 0 ā 100 mBars
Precision 0.2%EM Max
Stainless material
Digital indicator ARDETEM
4 digits classe1.6
Temperature regulation loop
Regulator EUROTHERM
Entry Pt100 relay exit
Plate lead line Pt100 on oil tank
Heating :
Thermal diving VULCANIC with safe thermostat
3000W 230VAC 4W/cmē
Cooling :
Water network circulation in exchanger piloting thanks to electrovalves
PERSON PROTECTION
Differential circuit breaker 30mA
Discharge valve at pump outlet
|