Teaching equipment : Reversible heat pump

 

Our categories

Reversible heat pump

DESCRIPTION


The reversible heat pump is delivered complete with instrumentation and includes a technical and instruction manual

This unit is designed and manufactured to industrial standards.

Use of the refrigerant R 134 a complies with new regulations regarding refrigerants
.
This unit can be used at different levels and for different courses.

 

Teaching equipment : Reversible heat pump - TCP 300

TECHNICAL SPECIFICATIONS
 

REFRIGERATING CIRCUIT

1. Hermetic refrigeration compression
 • Commercial type
 • Electric power: 1/8CV
 • Refrigerating power: 402 W
  - Condensing temperature: + 55°C
  - Evaporating temperature: + 5°C
2. HP manometer at compressor outlet
3. Water exchanger

  - Glass calander
  - Copper coil
  - Network water inlet and exhaust
  - Water flow rate measurement
  - Temperature measurement at inlet and outlet
4. Reversing cycle valve
5. Liquid tank
6. Dehydrator
7. Liquid state indicator
8. R134a flow meter

  - Magnetic transmission
  - Pointer display
  - Stainless steel



9. Thermostatic expansion valve
  - Pressure internal equalisation
  - Flow rate calibration orifice
10. Liquid shock-proof bottle
11. LP manometer
12. Safety instrument
13. Air exchanger

  - Forced convection
  - Copper tube and aluminium blade
  – Blade Pas: 4,2 mm
  – Refrigerating power: 325 W/
T 10°C
  – Exchange area: 1,4 mē

WATER EXCHANGER CIRCUIT

- Cold water tank
- Exchange circuit
- Recirculation pump
- Flow rate adjusting valve
- Flow meter
- Air convector

PEDAGOGIC APPLICATIONS

 

Study of the basic concepts of a R134a refrigeration installation
Calculation of the coefficients of exchange
Calculation of heat balance
Calculation of the efficiencies
Constructing enthalpic diagrams.

Study of the thermodynamic cycle of compression refrigeration equipment.
Determining
- efficiency
- energy balance
Study of the cycle reversibility concept

Teaching equipment : Reversible heat pump - TCP 300 schema

 

INSTRUMENTS
Temperature sampling at each transformation point
Voltmeter
Ammeter
Interfaces and connections for P.C (optional)

UTILITIES
Electricity : 230 VAC single phase – 50/60 Hz – 3 A

INSTALLATION VOLUME
Length : 1050 mm
Width : 800 mm
Height : 1500 mm
Weight : 70 kg

Download this page in PDF :

Reversible heat pump


Didatec Technologie - ZA du Parc 42490 Fraisses -  France -   Tel : 33 (0)4 77 10 10 10 -  Fax : 33 (0)4 77 61 56 49   
E-Mail : didatec.technologie@wanadoo.fr