PEDAGOGIC APPLICATIONS
Study of a SPLIT SYSTEM air conditioning system.
Functioning of a refrigeration system
Function of the different elements
Thermal results.
INSTRUMENTATION
- 2 pressure measurements on the High Pressure and Low Pressure
refrigeration circuit
- Refrigerating fluid (R410) flowrate
- Temperature of the characteristic points of the refrigeration
circuit and of the secondary fluid (air)
- Voltmeter and ammeter on the electric circuit of the
compressor which allows the computation of the power used.
|
UTILITIES
230 Vac – single phase – 6 A
DIMENSIONS
Length : 2155 mm
Width : 800 mm
Height : 1800 mm
Weight : 180Kg Download this page in PDF :
SPLIT SYSTEM air conditioning
|