TECHNICAL SPECIFICATIONS
1. Hermetic refrigeration
compressor
Commercial type
Refrigerant : R 404 A
- Condensing temperature : + 45° C
- Evaporating temperature :- 10°C
Maximum pressure : 29 bars
2. Air condenser
Forced convection
Copper tubes and aluminium blades
Mounted on the same frame as compressor
3. Liquid water tank
Vertical
Stainless steel
Exhaust valve 1/4” diameter
4. Refrigerant retrieval valve
Membrane made
straight passing ¼” diameter
5. Dehydration step
1/4” diameter solid cartridge dehydrator
1/4” diameter humidity indicator signal
6. Electromagnetic valve
Usually closed
1/4” diameter passing |
7. Thermostatic sensor
Internal pressure Regulator
Interchangeable flow caliper orifice
8. Air evaporator
Forced convection
Copper pipes and aluminium blades
- Condensing temperature : +45°C
- Evaporating temperature :-30°C
Electric freezing tool : 300 W
9. Shock proof liquid bottle
Stainless steel
Diameter 1/2"
10. Control and safety system
High pressure manometer
Low pressure manometer
High pressure gauge
Low pressure gauge
Combined gauge
Safety thermostat
Cold chamber
Insulation : 100 mm – polyurethane foam
Dimensions 830 x 830 x 2000 mm
Deficiency: 0.212W/m².°C (coefficient k)
Indicator |