Teaching equipment : Mounting of sanitary installations

 

Our categories

Mounting of sanitary installations

DESCRIPTION

 

The test bench is composed of various types of elements (flush toilet, washbasin, bidet, shower, water heater). They are fixed on a frame made of extruded aluminium.

The water runs, either in a closed circuit thanks to a supercharger, or in an open circuit with the network water

A set of copper collars is equipped with a flow meter

The drainage system (right sections) consists of transparent PVC tubes in order to observe the running effluent. The drainage system (sewage, effluent) can be achieved with a simple drain or with a drain that has sIHSndary ventilation (obtain the required parts from a plumbing supply)

 

Teaching equipment : Mounting of sanitary installations - IHS 100

 

 

The unit is delivered complete with instrumentation, technical documentation, and instructions

 

The hot and cold water supply comes from two distributors. The connection of the distributors to each element is made through exchangeable collars of various materials (Cu, PER) and various diameters

TECHNICAL SPECIFICATIONS
 

1 – Hanging toilet (water closet) (the top is protected by a transparent plate).

2 – Bidet
It is equipped with a manual mixer and a Ø40-siphon.

3 – Washbasin
It is equipped with a manual mixing battery and a transparent siphon with an easily changeable depth of seal (from 30 to 100mm). Exhaustion: Ø 32.

4 – Shower
It is equipped with a thermostatic mixing battery and a Ø40-siphon.

5 – Electric storage water heater: 75 litres (230V - single-phased – 1500W)
It provides the hot water required by the system.

6 – Supercharger – filter - counter – flow meter
The pressure in the network is regulated by a manometer that controls the supercharger. The supercharger is set so that the maximum flow rate in the system will be 36L/min (hot and cold water).

Manual pressure reducer : 0-5 b on cold water supply.

7 – Switch box
It permits the control of the water heater and the running of the supercharger.

8 – Drainage – Ventilation
Diameters are indicated on the scheme. A changeable piece of pipeline (T) permits to pass from a separative network to a unique one (with sIHSndary ventilation). The pipe between the sIHSndary ventilation and the washbasin's siphon is changeable (transparent hose). Possibility to put a diaphragm (Ø 50) in the common exhaustion (sheet gasket connector). The pipe of the sIHSndary ventilation (Ø 60) is dismountable.

9 – Water recycling tank
Constructed using PVC tubes (Ø 200), it is divided by a panel. It comes with 2 observation flaps for easy access for maintenance. Automatic controls shut down the system if water or effluent in the tank reaches too high a level. Changeable stickers are provided so that the purpose of the tank (effluent being collected) can be clearly indicated on the outside.

 

 

PEDAGOGIC APPLICATIONS

 

- Overview of a sewage disposal system
- Function of the various components
- Primary and sIHSndary ventilation of a network – depth of seal in a trap
- Calculation of basic flow rates and the probable flow rates
- Calculation of pipe diameters
- Study of the supercharger

Teaching equipment : Mounting of sanitary installations - IHS 100 schema


UTILITIES

Electricity : 220 V / 50 Hz
Network water and sewage

DIMENSIONS
Length: 3700 mm
Width: 800 mm
Height: 2000 mm
Weight: 300 kg (without water)


Download this page in PDF :

Mounting of sanitary installations


Didatec Technologie - ZA du Parc 42490 Fraisses -  France -   Tel : 33 (0)4 77 10 10 10 -  Fax : 33 (0)4 77 61 56 49   