Teaching equipment : Suburban sanitary facilities

 

Our categories

Suburban sanitary facilities

DESCRIPTION

 

• Balloon of storage and preparation ECS Bi-tension of 50 liters.
• Pumps looping ECS.
• adjuster Reducer water rate.
• Plate out of melamine (model cooks) with 5 individual basin equipped with various types of siphon.
• Various types of valves and fittings.
• Winnows balancing with catch of measurement of flows with mobile probes and numerical apparatuses.
• Isolating valves of the spherical type.
• Alimentation out of water conforms to the regulation in force.
• Electric box of order with relay off-peak hours.
• Piping out dismountable copper and connections.
• Drain out of transparent PVC for the evacuation.
 

Teaching equipment : Suburban sanitary facilities - TIF 100

 

 

• Manual and automatic vent cocks.
• Ventilation primary obstruable manually.
• Fixture of reading of temperature (alcohol thermometer) of pressure (dial pressure gauge) and measures flow (float rotameter).

 

TECHNICAL SPECIFICATIONS
 

1 : Service tank
2 : Sieve filter
3 : Water meter
4 : Unback valve
5 : Regulator
6 : Debimeter
7 : Sanitary expansion tank
8 : Degasor
 

9 : Water heater
10 : Safety group
11 : Thermometer
12 : Mixer tap with presence detection
13 : Simple mixer tap
14 : Mixer tap thermostatic wall
15 : Mixer tap EC + EF
16 : Tempered mixer tap
17 : Manometer
18 : Anti waterhammer

PEDAGOGIC APPLICATIONS

 

• To establish the energy balances of the various elements and the system.
• To analyze technology, the operation and the performances of sanitary facilities.
• To analyze the technology and the operation of regulation.
• To parameterize the equipment.
• To carry out the setting in water and the draining of whole or part of the installation.
• To carry out the disassembling and the reassembly of the apparatuses.
• To proceed to the operations of purging and draining.
• To carry out the balancing of loop ECS with fixtures and mobile.
• To carry out the adjustment of the equipment.
• To measure the effects of the dilation of the ECS.
• Measurement temperature and flow at the strategic point of the installation.
• To check the functionality of all the apparatuses of the installation.
• To carry out electric wiring like all the checks of use.
• Implemented electric of the instructions of risks.

Teaching equipment : Suburban sanitary facilities - TIF 100 schema


UTILITIES

Electricity : 220 V / 50 Hz
Water supply and outlet

DIMENSIONS
Length : 5000 mm
Width : 1200 mm
Height : 4000 mm

(tailored according to the shape of the room)
Weight : 400 kg (without water)


Download this page in PDF :

Suburban sanitary facilities


Didatec Technologie - ZA du Parc 42490 Fraisses -  France -   Tel : 33 (0)4 77 10 10 10 -  Fax : 33 (0)4 77 61 56 49   