TECHNICAL SPECIFICATIONS
Structure
- out of aluminum anodized on casters with brake
- stainless vat partly low with drainage sluice
Electric box n° 2:
- transparent cap
- contact of safety on opening of door
- support of platinum and connectors
- compatible for use of platinums of wiring or prewired proposed
- 1 platinum of direct starting
• : according to versions
Platinize prewired:
- 1 with integral direct starting
- 1 with progressive starting
- 1 with variator
Description of the compatible equipment:
Positive-displacement pumps in cases drink
- 1 volumetric motor-driven pump group with mechanical trimming gears
- 1 positive-displacement pump in parts spare without constraints for
activities of assembly mechanical disassembling/trimming
- 1 batch of defective parts and replacement for mechanical trimming
positive-displacement pump
Centrifugal pumps in cases drink
- 1 centrifugal motor-driven pump group with press packs
- 1 pump centrifuges without constraints in parts spare for activities of
assembly disassembling/press packings
- 1 pump centrifuges without constraints in parts spare for activities of
assembly mechanical disassembling/trimming
- 1 pump centrifuges with sealing by press packs for exchange of pump on
motor-driven pump group and/or activities of various maintenances
- 1 pump centrifuges with sealing by mechanical trimming for exchange of
the pump on motor-driven pump group and/or activities of various
maintenances
- 1 batch of defective parts and replacement for pump centrifuges with
mechanical trimming and press packs
|
Hydraulic system:
- 2 cylindrical polyethylene tanks high density (ref. 5) (1 tank for
pumping in load and the other for pumping in aspiration)
- Volume of each tank: 100 L
- System of draining and gauge of level
- Transparent Pipings PVC
- V1: Winnow flow with membrane
- V2, V3, V5: valves ¼ turn with spherical plug
- V4: valves ¼ turn with spherical plug bored for generation of pressure
losses
- 1 float flowmeter
- 2 pressure gauges for measurement of pressures to the aspiration and
repression Electric box n° 1:
- key lock for opening of the box
- disconnecting switch cadenassable
- circuit breaker and differential
- emergency stop with key
- button manufacture of order
- tachometric bill-poster
- selector of direction of walk
- ground lights
Platinums of wiring (option)
- 1 for direct starting
- 1 for integral direct starting
- 1 for progressive starting
- 1 for variator
Filtration (option):
- 2 filters cartouches
- 1 batch of cartouches to sampled calibration
Control/instrumentation (option)
- 3 adjustable sensors of level usable indifferently on the 2 tanks
- 2 sensors reed/THEY on flowmeter
- 1 flowmeter at analogical exit
- 2 pressure gauges/pressure controller with 1 threshold with repression
and the aspiration
- 2 pressure gauges with analogical exit
Also compatible: kits of vibratory analysis MBP011 and
alignment MBP 021/to consult us
|