TECHNICAL SPECIFICATIONS
• Hydraulic circuit
Polypropylene tanks, transparent PVC pipeline
• Engines
- Tube wells pump associated to a flow vectorial control variator –
serf-priming
- Pad tank pump in charge of the aspiration
• Sensors
- analogue level on the capacitive type pad tank
- TOR level on the pad tank and relay conductive
type tank
- analogue output on the pad tank
|
• Automatism
- industrial programmable automation with a programmed keyboard
E/S TOR
E/S ANA for level sensors and output and frequency variator
- Control
PID for level and flow rate
TOR for level
• Checking
The unit can be connected to the checking system on a PC in order to
collect working parameters and the alarm management
|