Teaching equipment : Regulation of a Heat Exchanger

 

Our categories

Regulation of a Heat Exchanger

DESCRIPTION

 

The unit is delivered complete with instrumentation, technical documentation, and instructions.

Designed and manufactured to industrial standards.

This unit is designed for various levels and fields of study

Inlets and outlets are connected using Ø 4 mm female safety sockets

It is possible to connect this unit in series with another regulation unit and to use the valve as a main control.

 

Teaching equipment : Regulation of a Heat Exchanger - RCT 101

 

 

Options:
– Interface and software for PC
– Utilities module

TECHNICAL SPECIFICATIONS

A. Compressed air
B. Water return
C. Water supply

T1-T2-T3-T4 : Temperature probes

Pt 100
Ω – class A
Stainless steel 304 L

Temperature indicator
Display 0.1°C
Recopy of the measure (4-20 mA) on jack - Ø 4 mm

Thermoregulator group
Capacity : 5 litres
Adjustment from +20°C to +100°C
Power 1600 W
Incorporated regulation at
±0.5°C
Circulation pump

Exchanger
Monotubular – stainless steel
External tube covered by a thermal insulator
Hot water into the internal tube
Cold water into the external tube
Quick and interchangeable connections on the cold-water network for the lead through in co or back-run

Electromagnetic flow meter
PFA covering, stainless steel electrodes
Local display, outlet 4-20 mA

Regulation valve
Stainless steel body
Variable Cv
Pneumatic positioner and actuator

R1 – R2 : PID type regulator with microprocessor
Accuracy class 0.2
Configurable scale range
Continue, logical, relay outlet
– Proportional band from 0.5 to 1000%
– Integral action time from 0.1 to 100 min
– Derived action time from 0.01 to 10 min
Self-adaptive: the PID parameters are calculated by the regulator for an optimized regulation
Numerical outlet : MODBUS RS 232
One of the regulators has an external control inlet for regulation in cascade

Variable section flow meter
Rotameter : accuracy
±3% of the full scale

Perturbation valves - 1/4 turn
On hot and cold circuit

1/4-turn valves for connection in series (S)

PEDAGOGIC APPLICATIONS

 

• Technical data for the elements of a regulation loop
• Sensor – regulator – actuator – perturbing element
• PID or self-adaptive
• Configuration of the regulator
• Characteristic curves (temperature, valve opening, time of response, etc…)
• Study including advantages of regulation in cascade
  – Co-run
  – Back-run
  – Laminary/turbulent flows

Teaching equipment : Regulation of a Heat Exchanger - schema RCT 101

UTILITIES
Electricity : 230 Vac – single-phase
Water : 10 L/min – 3 bar (44 psi)
Compressed air : 6 bar (90 psi) maximum

DIMENSIONS AND WEIGHT
Length : 780 mm
Width : 570 mm
Height : 590 mm
Weight : 50 kg

 

Download this page in PDF :

Regulation of a Heat Exchanger



Didatec Technologie - ZA du Parc 42490 Fraisses -  France -   Tel : 33 (0)4 77 10 10 10 -  Fax : 33 (0)4 77 61 56 49   
E-Mail : didatec.technologie@wanadoo.fr