TECHNICAL SPECIFICATIONS
Absorption column
• Borosilicate glass
• Diameter : 50 mm
• Height : 1200 mm
• Supply tanks - polyethylene
Supplying diaphragm pump
• Stainless steel top - 316 L
• Flow rate : 22 L/h
Extract receiver – 2 L
• Borosilicate glass
Receiver for purified gas
• Borosilicate glass
Flow meter for inert gas
• With a needle gate
• Flow rate 0-100 L/min STP |
Flow meter for gas to be absorbed
• With a needle gate
• Flow rate 0-48 L/min STP
Dispatching supplying plates
• Stainless steel – 316 L
Pressure losses panel (in mm of water)
Barometric leg
• Makes it possible to control the phase in the top column
TEMPERATURE SENSORS
T1 : Solvent inlet
T2 : Top column temperature
T3 : Substructure temperature
T4 : gaseous mix inlet |