TECHNICAL SPECIFICATIONS
1. Feed tank 35 L in polyethylene
2. Stainless steel centrifugal feed pump
3. Feed rotameter 0-16 L/min
4. Heating tube (process) condenser
Stainless steel ribbon pan – 7 tubes 20-240 mm – length 0.85 m
Below stainless steel collander, inside diameter 100 mn – 30 bars working
pressure (430 psi)
0.4 m² exchange surface, exterior non-conducting heat, DN100 superior
protecting glass
5. DN 100 glass cyclone separator
6. DN 100 glass level pot, cover and stainless steel
7. Stainless steel centrifugal return pump
8. Return rotameter 0 – 200 L/h
9. Condenser (process, evaporator
Tube stainless steel double pipe coils 10-12 mm in twice 9 threads (50 and
110 mm)
Global plunger 4.5 m exchange surface 0.15 m²
Glass collander DN 150 cover and DN 100 inlet protecting glass stainless
steel
10. DN 150 glass 5 L solvent receiver cover and stainless cooling
11. DN 150 glass 5 L concentrator cooling
12. Stainless steel pipe coil solvent cooling
13. Stainless steel pipe coil concentrator cooling
14. R134a compressor
15. Sheet metal case
16. flow meter 0 – 200L/h |
17. Thermostatic pressure reducing valve
18. Starting electric heating cartridge
19. Leak automatic micro valve for adjustment
20. Vacuum pump
INSTRUMENTATION
P1 Bourdon manometer – at the condenser outlet
P2 Bourdon manometer – at the evaporator outlet
PT4 Absolute pressure transmitter to adjustment
T1 Compressor outlet temperature sensor
T2 Condenser outlet temperature sensor
T3 Evaporator inlet temperature sensor
T4 Evaporator outlet temperature sensor
T5 Heating tube outlet temperature sensor (process)
SPECIFICATIONS
This unit separates two components of a liquid mixture such as water and
glycerine.
- Refrigerant : R 134 a
- Power at the heating tube (condenser R 134 a : 6 kW
- Condenser temperature : R 134 a : + 65°C maximum
- Evaporation temperature : R 134 a : +12°C
- Temperature measurements
- Through sensors Pt 100
Ω for the
process
- Through thermal converter type T for the R 134 a
- Pressure measurement through Bourdon manometer |