TECHNICAL SPECIFICATIONS
1- Supply tank - 4 sections
Solution of HCl
Solution of NaCl
Water to be treated (or solution)
Demineralized or distilled water
Volume : 100 L – PVC
2- Supply pump
Centrifugal (0-30 L/h) – electromagnetic
P = 0.37 KW
3- Rotameter
Stainless steel – with adjustment valve
0-100 L/h
4- Manifold – 3 valve set
Supply toward anionic column
Supply toward cationic column
Regeneration of the columns |
5- Cationic resins
2 interchangeable types of resins, hard or soft
Transparent PVC column - DN50
Length 500 mm
6- Anionic resins
2 interchangeable types of resins, hard or soft
Transparent PVC column - DN50
Length 500 mm
7- Conductivity-pHmeter
Measurement on the line of the conductivity and pH
Conductivity : range 0-1999.9 µS/cm
pH : 0-14
Accuracy:
±
2%
Maximal temperature: 50°C
Possible to work with resins in series or in parallel, in back run or
co-current. |