TECHNICAL SPECIFICATIONS
1-2-Supply tank
- High density polyethylene
- Volume : 20 L
3-4-Supply pump
- Dosing pump with diaphragm
- Polypropylene body
- Maximal flow rates at 3 bar (45 psi): 8 L/h
5- Neutralization section
- Volume = 5 L PVC
- Agitator
- pH electrode and indicator for neutralization
- Temperature sensor (Pt 100 type) and indicator
6- Flocculation section
- Test with Jar test flocculator for the optimization of the quantity of
flocculent or coagulant
- Volume 5 L – PVC
7- Agitators
- Variable speed: 0-2000 R.P.M. at 100 Ncm
- 316 L stainless steel gear and modulus with propeller
|
8- Decantation tank
- PVC
- Volume 100 L
- Recirculation rail and 30 %-fall for the outflow
9- Recirculation pump
- Centrifugal pump - P = 0.37 kW
- AISI 316 l stainless steel body
- Maximum flow rate: 1500Ll/h at 1.5 bar(21 psi)
- Rotameter - 0-500 L/h
10- Supply tank of waters to be treated
- High density polyethylene
- Volume: 150 Lwith low point of evacuation
11- Supply pump
- Centrifugal pump - P = 0.37 kW,
- AISI 316 L stainless steel body
- Maximuml flow rate : 1500 L/h at 1.5 bar (21 psi)
- Rotameter - 0-500 L/h
Option : Jar test flocculator – 6 stations to determine the
quantity of flocculents or coagulants to treat and optimise waste waters. |