TECHNICAL SPECIFICATIONS
A. Air distribution chamber
B. Centrifugal fan with variable flow rate
C. Transparent cooling tower
With three different fittings :
Rough cellular
Fine cellular
Cellular with punched surface
D. Diaphragm for the air flow measurement
E. Differential pressure manometer
F. Water thermoregulator group
Water volume : 7L
Power : 3500W
Low level security for resistance protection
G. Centrifugal circulation pump
1.8m3/h – 21 mCE |
H. Axial turbine flow meter
0-150L/h
I. Control valve for hot water
J. Automatic water addition
The water is in a graduate tank (consumption measurement)
The extra electrovalve is controlled by a level sensor in the F-group.
t. Temperature measurement
T1 : group water
T2 : tower starting water
T3 : tower return water
T4 : tower entry air
T5 : tower outlet air
h. Relative humidity measurement
H1 : tower entry hygrometry air
H2 : tower outlet hygrometry air |