BOO CO2 - CO2 booster system
Need more information?
Contact us- Identification of the components of a Booster system
– Commissioning and verification of operations
– Study of the basic concept of a two-stage CO2 refrigeration system operating at two temperature levels.
– Study of the thermodynamic cycle on a pressure–enthalpy diagram.
– Study of control in the three operating cases listed in the source: low-temperature and medium-temperature refrigeration; low-temperature and medium-temperature refrigeration.
– Study of the effect of pressure rise during a malfunction, using the independent safety unit.
– Study of capacity control on the medium-temperature compressor using a variable frequency drive to adjust its rotational speed, and capacity control on the low-temperature compressor in response to changes in internal loads.
– Comparative study of the regulator to manage the different phases of operation
– Handling CO2 refrigerant for maintenance operations such as replacing a filter-drier. Specialised tools (manifold and detector) are included.
(1) Structure:
– Lightweight frame: bolted anodised aluminium profiles with sealing strips for the cold-room section, and a steel frame for the condensing-unit section.
(2) The machine consists of:
– A low-temperature semi-hermetic CO2 compressor, approximately 2 kW, fitted with a variable frequency drive operating from 30 to 70 Hz.
– Two medium-temperature semi-hermetic CO2 compressors, approximately 8 kW, fitted with a variable frequency drive operating from 30 to 70 Hz.
– All equipment required by the regulations (dual safety valves, relief valve) and for CO2 use is included, along with CO2-specific servicing and maintenance tools.
– A fully equipped industrial low-temperature cold room.
– A 2.6 kW CO2 evaporator matched to the low-temperature compressor, fitted with an electronic expansion valve.
– A variable heat load matched to the evaporator capacity.
– A fully equipped industrial medium-temperature cold room.
– An 8.1 kW CO2 evaporator matched to the medium-temperature compressor, fitted with an electronic expansion valve.
– An air-cooled gas cooler integrated into the frame.
– Oil separator, reservoir and oil return with electronic level control.
– A system that starts the medium-temperature compressor during prolonged shutdowns when power is available but no refrigeration is being produced.
– An independent safety unit that controls liquid receiver pressure during servicing when no electrical power is available.
– Safety valves all connected to a common manifold at the bottom, with provision for discharge outdoors.
– An electronic high-pressure control valve
for the receiver
– A liquid line with a replaceable-cartridge filter-drier and the valves needed for replacement, a liquid sight glass, relief valves and a heat exchanger for enhanced subcooling.
– A CO2 gas detector
– All pipework complies with the standards for CO2 use: K65 copper-iron (CuFe) tubing.
(3) Instrumentation:
- 16 temperature sensors on the cooling circuit with analogue output
– 6 temperature sensors on air at exchangers with analogue output
– 4 pressure sensors on the cooling circuit with analogue output
– An electrical power analyser measuring voltage, current, phase shift and the various electrical power quantities.
– A system schematic on a touchscreen, with LEDs showing which electrical devices are operating.
(4) The electrical part includes:
– An electrical supply box
– Standard safety components (main isolator, residual-current circuit breaker, earth connection and white indicator light).
– A thermal-magnetic circuit breaker for each component.
– Signal lights for each element
– Measurements displayed on a 10-inch touchscreen, including a system schematic and real-time graphs.
– The data acquisition system can connect to a PC locally via Ethernet or Wi-Fi, or remotely via the internet. All data can be retrieved in an Excel-compatible file.
- Power supply machine : 400 Vac – 50 Hz – 16 A
• Type of power supply: 3 phase(s) + Neutral + Earth.
• Backup electrical supply for the pressure-maintaining unit: 230 Vac – 50 Hz – 16 A
• Type of power supply: 1 phase(s) + Neutral + Earth.
• Safety valve discharge: diameter 7/8 inch
• Dimensions (L × W × H, mm): 4500 x 1400 x 1900
• Weight (kg): 1150