PTR 010 - Cooling tower trainer
The PTR010 trainer allows the study of psychrometric phenomena that allow the processes of humidification and dehumidification, a process which occupies an important place in applications relating to the treatment of air in common use as in industry for example. It also allows the study of a particular application which consists of cooling hot water with air.
Also, to meet these didactic requirements, we chose the forced refrigeration solution, which perfectly shows the process to be studied and which also allows simple and explicit experiments to be carried out. Users will be able to perform simple experiments and thus, assimilate the key concepts of the control principles necessary for the operation of the cooling tower and the installation procedure.
The robust design of this device makes it suitable for use in schools.
Anodized aluminum structure gives it a very robust as well as a flexible integration into your premises.
The manufacturing of this equipment meets European Machine Directive.
Need more information?
Contact us- Identification of the components of a cooling tower
- Commissioning and readings of measurements (T °, RH, flow, etc.)
- Study of heat exchange between water and air
- Thermal-efficiency balances
- Comparison of two types of packing
- Monitoring of the evolution of the air on a psychrometric diagram
The trainer is installed on an aluminum profile structure equipped with four directional brake castors.
It has an electrical box with general power disconnector and 30mA differential circuit breaker.
- Stainless steel hot water tank
Volume of water: 15L
Max water temperature: 55°C
Side level indicator
Low-level safety for resistance protection
- Electric heating resistance
Power : 3000W
Built-in safety thermostat
- Centrifugal pump
Maximum flow rate: 20L/min
Maximum pressure: 3.5 bars
V3. Hot water flow controlvalve with a needle
- Automatic water top-up
The top-up water is contained in a transparent 5L PVC graduated tank (consumption measurement)
The top-up solenoid valve is automatically controlled by a level sensor located in the water tank (1.)
- orifice plate for the airflow measurement
- Water diffusion nozzle in the cooling column
- Transparent coolingcolumn
Trim height : 565 mm
Passage section: 150 x 150 mm
2 columns are provided (see details below)
- Distribution chamber
Recovery of water flowing out of the column
Air distribution in the column
- Centrifugal fan
EC type motor
Speed variation per potentiometer located on the enclosure
- Instrumentation
Temperature measurement
t1 : tank water
t2 : water inlet tower
t3 : water output tower
t4 : air inlet tower
t5 : air output tower
Relative humidity measurement
h1: hygrometry air inlet tower
h2: hygrometry air outlet tower
Differential pressure measurement
dP1: Column pressure drop
dP2: differential pressure of the diaphragm (5.)
Debit
Q1: Hot water flow
- Electrical supply : 230 VAC – 50 Hz – 20 A
- Water : filling of the tanks
- Dimensions: (LxWxH mm): 1350 x 755 x 2050
- weight (Kg): 155