CRM 013 - Study of split system air conditioner with small room
The CRM013 training unit is delivered complete, instrumented with technical manual and practical work. It is based on a Split air conditioning system of a popular brand on the market with a power of 2.5KW. Students will first have to familiarize themselves with the system by discovering the different components. They can then put it into operation and check that the operating parameters are correct. When the system is operating at its nominal speed, they will then have to use the instrumentation made available to them to take readings allowing them to make a complete assessment of the installation and to trace the refrigeration cycle. They will also be able to calculate the power involved and see the energy efficiency of the system.
The rugged design of this equipment makes it perfectly suited for use in a school setting.
Its anodized aluminum structure on wheels gives it a very high robustness as well as great flexibility of integration into your premises. The manufacture of this equipment complies with the European Machinery Directive
Need more information?
Contact us- Study of a separate air conditioning system (SPLIT SYSTEM INVERTER)
- Identification of plant components
- Commissioning and operation of a refrigeration system
- Measurement of operating parameters (temperatures, pressures, power consumption)
- Basic maintenance operations (cleaning of filters, etc.)
- Role of the different bodies
- Thermal balance on the fluid part and on the air part
- An aluminium profile structure on braked, directional castors.
Two parts: one with the "outer part" condensing unit and a closed part with the "inner part" evaporator.
The "inside" compartment is equipped with an access door allowing a standing person to pass through. - Split system air conditioning with variable (inverter) and reversible (heat or cold) energy production:
-Compressor power 2.5KW.
-Refrigerant used: R32
-A finned condenser type exchanger with variable speed fan
-A finned evaporator type exchanger (indoor unit) with variable speed fan and flow orientation blades - Condensate collection tank in the lower part
- BP pressure sensor with display on the touchscreen
- HP Pressure Sensor with Touchscreen Display
- Temperature measurements of the characteristic points of the circuit by fixed thermocouple type probes and indication on the touch screen on the electrical box (12 measuring points)
7. Measurement of the electrical power consumed and display on the touch screen on the electrical box (instrument for the study of power variation) - Refrigerant flow measurement with magnetic transmission float flow meter. The flow rate is only measured when the system is running in air conditioning mode.
- The bench is supplied with portable measuring devices allowing students to place themselves in the real case of an HVAC technician (direct measurement on the system).
-a portable thermometer
-a propeller anemometer
-a thermo hygrometer - The bench is equipped with an electrical box that complies with the Machine Directive for personal safety. It is equipped with a padlockable power disconnect switch, a punch-type emergency stop button, a residual current circuit breaker with 30mA protection, grounding of all elements, and a 7" color touch screen
On-screen pressure gauges Temperature display
- Electrical supply : 230 Vac– 6A
- Power Supply Type: 1 phase(s) + Neutral + T
- Dimensions: (LxWxH mm): 1565 x 800 x 1875
- weight (Kg): 120