HFF 200 - Refrigerant transfer trainer with semi hermetic compressor (water/wate)
The HFF200 bench is designed to train learners in the handling of refrigerants. The installation is based on a refrigeration cycle operating with R1234YF. It includes the main components of a positive installation, a compressor, a water condenser, a liquid tank, an oil separator, a regulating solenoid valve, an expansion valve, a water evaporator and a liquid blow bottle. Schrader service valves and fittings allow learners to connect a manifold for loading, recovery and operation verification operations.
Energy dissipation is done by a closed-loop water circuit including a unit heater to dissipate calories and a buffer balloon. A thermostatic control box will control the operation of the solenoid valve (pump-down regulation). A button allows the pressure switches to be passed to force the operation of the compressor and facilitate the removal of manifolds.
The rugged design of this equipment makes it perfectly suited for use in schools. Its anodized aluminum structure on wheels gives it great robustness and flexibility of integration into your premises. In the lower part, the bench has a storage area equipped with a door with key closure (storage of tools).
The manufacture of this equipment complies with the European machinery directive. This equipment can be used alone or combined with other compatible equipment in our range (see last part of this document).
Need more information?
Contact us- Identification of the components of a refrigeration system
- Commissioning and adjustments (regulator, regulator) of a refrigeration system
- Refrigerant recovery and charging procedure (requires OUT100 additional tooling)
- Control component adjustment (BP pressure switch, HBP pressure switch)
- Maintenance operations on a refrigeration installation, replacement of the dehydrator, replacement of a piece of BP line, replacement of compressor oil etc … (Requires OUT100 add-on tooling)
- Plot the refrigeration cycle on an enthalpy diagram to check the operation of the installation
- Use of R1234YF fluid
- Semi-hermetic compressor with service valves
2. Safety valve on the HP line
3. Plate exchanger type water condenser
4. Steel liquid tank
5. Oil separator with compressor return line
6. HBP safety pressure switch
7. BP control switch for pump-down
8. Ball valve with Schrader fitting to isolate sections of piping and allow fluid recovery
9. Filter dryer
10. Fluid status indicator
11. Control solenoid valve
12. Internal equalization regulator
13. Plate exchanger type water evaporator
14. Anti-liquid blow bottle volume 1.5L The bench also includes:
-a power supply box with differential circuit breaker, punch stop, general disconnector and a 2P + T socket to connect accessories (pump, recovery station …)
-a digital thermostatic controller with probe on the water circuit. The box controls the solenoid valve (pump down regulation).
-a push button allows to pass the pressure switches to facilitate the removal of the manifold
-a closed-loop water network for calorie dissipation including a buffer bottle, expansion tank, circulator, unit heater, water flow meters and two flow control valves.
-The bench is pre-filled with a water/glycol mixture
-a storage area in the lower part of the frame with access by a door. A key lock secures the storage.
- Power supply: 230 Vac – 50 Hz – 10 A
- Power supply type: 1 phase(s) + Neutral + Earth.
- Dimensions: (LxWxH mm): 1550x 765x 1870
- Weight (kg) : 180