TVP 500 - Steam production and supply
Need more information?
Contact usPractical exercises on real elements of steam production and supply
- Study of a complete plant for production and supply of steam
- Pre control, start up and adjustment
- Plant operating procedure
- Process parameters optimization
- identification of all components
- study of steam technologies (separator, steam traps, reducing valves, control valves…)
- – Comparison of various technologies
- – Preventive maintenance water quality check up
- – Study of heat exchanges
- – Study of the steam cycle
- Safety concepts about a process plant
Steam boiler:
Steam flow : 250kg/h
Working pressure : 9 bars
Burner feeding :Natural gas or fuel (on demand)
Working mode : permanent presence
The boiler come with :
- pressure manometer
- two level glass sights
- safety valve
- draining valve
- check valve and feeding valve on the water circuit
- electric cabinet with audible alarm
- water level controller
- pressure controller
Utilities skid :
It comes with :
- electric cabinet supplying power to all the elements
- water feeding line with a water meter, a backflow preventer, a filter, a manometer, a pressure reducer and all necessary
- a volumetric softener with salt tank
- some valves for samples
- water tank (250L) made of stainless steel with lateral level sight
- a dosing pump
Steam supply :
It comes with:
Steam feeding :
- it is connected to the boiler outlet
- it includes a water separator
- it includes a Y filter
- it includes a vortex flow meter (steam flow)
- it includes pressure and temperature measurements
- condensates are pumped back to the water tank
Reducing valves:
- the line allows to test two different reducing valves
- each reducing valve has a stop valve before and after and a Y shaped filter
- two different technologies are used (pilot operated pressure reducing valve and direct acting reducing valve)
- a third line with a valve allows to bypass reducing valves
Control valves :
- the line allows to test two different control valves
- valves control the steam flow, depending from the water temperature at the outlet of the exchanger
- each control valve has a stop valve before and after and a Y shaped filter
- there is an electric actuator and a mechanical actuator
- a third line with a valve allows to bypass control valves
Steam condenser :
- the exchanger is tubular type and is cooled with water
- the cooling power is designed to fit with the maximal steam flow generated by the boiler (about 130KW)
- it is equipped with temperature sensors on the different circuits
- it is equipped with a water flowmeter
- it includes a vacuum breaker to avoid degradation when the steam condensates
- condensates go to steam traps
Steam traps :
- the line includes five steam traps
- each steam trap consists in a different technologie (thermodynamic, inverted bucket, bimetallic, ball float and balanced pressure)
- each steam trap is equipped with a sight glass and stop valve
- condensates go back to the water tank
Water cooling circuit :
- Cooling unit outside
- the cooling circuit includes a centrifugal pump
- Cooling unit :
- Average power : 140KW
- local electric cabinet with emergency stop
- fans are controlled by a temperature switch
- the structure is corrosion resistant
- fans are protected
- stop valves on the outlet and inlet
- drain valve
Others characteristics :
- the equipment include a pump (operated by steam) for condensate return
- the equipment also include a blowdown tank.
- the equipment will be fitted to laboratory
Water : 3 bars – 30L/min
Natural gas : 300mbar or Fuel (250L)
Electricity :400VAC threephased+neutral+earth-32A
Smoke exhaust : 125 mm chimney
Water drain on the floor
length : 6 m
width : 5 m
height : 2,3 m
weight : 3,2 t