TCF 101 – Banc de chaudières murales

Energy engineering Heating

TCF 101 - Wall mounted boilers bench

The TCF101 bench allows the study of two wall-mounted gas boilers.

The first boiler is basic, it includes a DHW circuit and a direct heating circuit. The second boiler is more advanced and has a DHW circuit, a direct heating circuit and a heating circuit with control by three-way valve (integrated control in the boiler).

The trainees must firstly identify the components of each boiler then proceed to commissioning thereof.

When the circuit will be at temperature, then they can make the calculations of thermal power and of consumption (gas).

Each module is also equipped with a DHW circuit instrumented in order to measure the flow rates and the operating temperatures

Add several machines to your selection for a single combined quote.

PDF documentation

Need more information?

Contact us
  • Identification of the components of a wall-mounted gas boiler and the associated circuits (DHW and heating)
  • Visualization of the boilers implementation
  • Commissioning and configuration of each boiler regulations
  • Measurement of flow rates and temperature and calculate the thermal power of the heating circuit
  • Study of the DHW circuit and flow rates measurement and temperature

Study of the boiler and measuring of the gas consumption